Vornado Air, LLC
415 East 13th Street, Andover, Kansas 67002
CL3-0168 RA
CL7-0168 RA, V00
Designed, engineered and supported in Andover, Kansas.
Montaje, diseño y soporte en Andover, Kansas.
Questions or comments?
¿
Prequntas o comentarios?
800.234.0604
pERSOnaL VORtEx ciRcuLatiOn
tRuSt
It is said that trust isn’t given, but earned. For decades Vornado
has been earning the trust of our customers by offering them only
the best. Vornado provides the highest level of performance,
coupled with the highest level of support available. Complete
satisfaction with no exceptions – this is Vornado’s promise to you.
If you are not satisfied for any reason, please contact us.
Knowledgeable representatives are available at 1-800-234-0604
from 8:00 AM to 5:00 PM CST. A wealth of additional support is
and the entire staff at our Andover, Kansas headquarters – thank
you for selecting Vornado.
Sincerely,
Bill phillips
CEO, Vornado Air
High Heat, Low Heat and Fan Only Modes
For year-round use.
1
2
750W Heating Element
Effectively heats your personal space using 50%
less energy than traditional space heaters.
LEaDERS in aiRfLOw tEcHnOLOgy™
3
4
5
Deep Pitch Blades
Churn through the air for high output.
Air Guide Enclosure
Sculpts the heated air into a tight beam.
Zippi™
fLippi™
wHOLE ROOM
aiR ciRcuLatORS
AirTensity™ Spiral Grill
Extends the distance of air movement up to 15 ft.
Ordinary heaters provide only localized heat. Heat immediately rises
to the ceiling, resulting in cold and hot spots in the room. Vornado’s
unique Vortex Action delivers continuous, uniform heat surrounding
everyone in the room in a warm, comfortable temperature.
wHOLE ROOM
HuMiDifiERS
tOwER
ciRcuLatORS
wHOLE ROOM
HEatERS
English
3
iMpORtant inStRuctiOnS
REaD aLL inStRuctiOnS BEfORE uSing tHiS HEatER. SaVE tHESE inStRuctiOnS
Please visually inspect all internal and external components before connecting to electric current. If any damage is found,
DO NOT USE THIS UNIT and contact Vornado Air LLC at 1-800-234-0604.
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock,
and injury to persons, including the following:
Read all instructions before using this heater.
Do not run cord under carpeting. Do not cover cord with throw rugs,
runners, or similar coverings. Do not route cord under furniture or
appliances. Arrange cord away from traffic area and where it will not be
tripped over.
This heater is hot when in use. To avoid burns, do not let bare skin touch
hot surfaces. Use handles when moving this heater. Keep combustible
materials, such as furniture, pillows, bedding, papers, clothes, and
curtains at least 3 feet (0.9 m) from the front of the heater and keep
them away from the sides and rear.
To disconnect heater, turn controls to off, then remove plug from outlet.
Do not insert or allow foreign objects to enter any ventilation or
exhaust opening as this may cause an electric shock or fire, or damage
the heater.
Extreme caution is necessary when any heater is used by or near children
or invalids and whenever the heater is left operating and unattended.
Always unplug heater when not in use.
To prevent a possible fire, do not block air intakes or exhaust in any
manner. Do not use on soft surfaces, like a bed, where openings may
become blocked.
Do not operate any heater with a damaged cord or plug or after the
heater malfunctions, has been dropped or damaged in any manner.
Discard heater, or return to authorized service facility for examination
and/or repair.
A heater has hot and arcing or sparking parts inside. Do not use it in
areas where gasoline, paint, or flammable liquids are used or stored.
Do not use outdoors.
Use this heater only as described in this manual. Any other use not
recommended by the manufacturer may cause fire, electric shock, or
injury to persons.
This heater is not intended for use in bathrooms, laundry areas and
similar indoor locations. Never locate heater where it may fall into a
bathtub or other water container.
4
English
HOw tO uSE
Using your Vornado® VH101 is easy. Just follow these simple steps:
1. Position your VH101 so the vortex beam of warm air is directed
across the room unobstructed. Position it in a location that is
representative of the room temperature. The unique side-angled
air inlets allow the heater to be placed closer to walls than possible
with most ordinary heaters (but do not place close to
Always plug heaters directly into a wall outlet/receptacle. Never
use with an extension cord or relocatable power tap (outlet/power
strip).
combustibles). Avoid areas of temperature extremes such as
cold drafts and heat registers. Please refer to IMPORTANT
INSTRUCTIONS at the beginning of this owner’s guide.
Operate this heater only in its upright position. Do not operate
this heater on an elevated surface such as a shelf or desktop. Use
only while placed on the floor.
2. Plug the power cord into a standard wall outlet.
3.
Set the POWER switch to ON. The amber light will be on anytime
the POWER is on.
This heater is equipped with a thermal safety shut-off system,
designed to turn off the heater when an internal overheating
condition is detected (see How To Use “RESETTING YOUR
VORNADO HEATER,” to determine how to check and
reset the heater).
4. Set the mode switch to HIGH or LOW HEAT, or select the center
position on the switch for FAN ONLY.
5.
Any servicing should be performed by an authorized
service representative.
This appliance has a polarized plug (one blade is wider than the
other). To reduce the risk of electric shock, this plug is intended
to fit in a polarized outlet only one way. If the plug does not fit
fully in the outlet, reverse the plug. If it still does not fit, contact a
qualified electrician. Do not attempt to defeat this safety feature.
6. Save the retail carton and cord twist-tie to use when storing the
heater in the summer and spring seasons. Secure the cord by
using the provided twist tie, or if you no longer have the twist-
tie, simply wrap the cord with a rubber band. Place the heater
back into the retail carton and close top flaps to avoid dust
accumulation on and in the heater.
Do not operate this product with any electronic speed-control
device on the same circuit.
Do not use heater to dry human or animal hair/fur or articles
of clothing.
SaVE tHESE inStRuctiOnS
English
5
VH101 OpERating cOntROLS
RESEtting yOuR VORnaDO HEatER
pOwER On/Off
1
Your Vornado Heater has a multi-level safety shut-off system designed
to prevent overheating. Overheating may occur when the inlets or
outlet are blocked, a foreign object prevents the blade from turning,
or the appliance tips over. If this happens, the safety shut-off system
will cut power to the heat element and you will need to manually reset
the heater.
2
MODE SwitcH
HigH HEat
750 watts
1
2
fan OnLy
Fan will run continuously
Set the POWER switch to OFF and unplug the unit.
Remove any obstructions.
1.
2.
3.
4.
5.
LOw HEat
350 watts
Wait 5–10 minutes, allowing the unit to cool down.
Plug in the unit and place in desired position.
Set the POWER switch to ON. Your Vornado Heater should now
function normally.
If the safety shut-off system repeatedly shuts off your heater or if it
will not reset after following the above procedure, DO NOT
ATTEMPT TO DISASSEMBLE THE UNIT. Call Vornado Consumer
Services Department toll-free at 1-800-234-0604.
caRE & MaintEnancE
The VH101 has no user serviceable parts. Do not disassemble the
unit as doing so will void your warranty. If service is required, return
your heater to Vornado (see Warranty section for instructions).
The motor inside your VH101 is permanently lubricated and requires
no oiling.
Because your VH101 moves air, it will require regular cleaning. Be
sure to unplug the unit prior to any cleaning activity. Use a vacuum
cleaner with the brush attachment to clean any accumulated dust on
the front grill and the side air inlets.
6
English
OpERating tipS
aDVancED SafEty fEatuRES
In smaller areas, you might prefer to set the mode switch to LOW.
TIGHT GRILL SPIRALS
Resists curious fingers.
In larger spaces, your Vornado® Personal Vortex Heater, or VH101, will
function most effectively with the MODE switch set to HIGH. In the HIGH
position, the vortex beam of air will gently keep the air circulating in the room
for even, uniform heating.
Your VH101 can function as a personal fan for cooling.
COOL TOUCH CASE
Your VH101 draws up to 6 amps of electric current. If using your VH101 on
HIGH HEAT causes your home’s circuit breaker or fuse to trip, we offer the
following suggestions:
Safe to touch, even on high heat setting.
Try turning off other electrical appliances that run on the same circuit as
your VH101.
AUTOMATIC SAFETY SHUT OFF SYSTEM
If airflow becomes blocked and overheats, power to the
heating element and fan shut off.
Run your heater on LOW HEAT.
Have your electrician add an additional circuit to your home’s electrical system.
ALWAYS USE COMMON SENSE WHEN USING THIS AND/OR ANY
ELECTRICAL APPLIANCE.
TIP-OVER PROTECTION
If tipped more than 10 degrees in any direction, heat
and fan functions immediately shut down.
IDEAL 120°F EXIT AIR TEMPERATURE
Warm enough to heat your personal space.
English
7
VORnaDO aiR LLc
3-yEaR LiMitED waRRanty
Vornado Air LLC (“Vornado”) warrants to the original consumer or
purchaser that this VH101 heater (“Product”) is free from defects in
material or workmanship for a period of three (3) years from the date of
purchase. If any such defect is discovered within the warranty period,
Vornado, at its discretion, will repair or replace the Product at no cost if the
Product is returned to Vornado postage-paid. Repairs not covered by the
warranty or outside the warranty period will require a fee to cover the cost of
materials, handling and shipping.
Staple or attach your original sales receipt to this Owner’s Guide. Please also
write your Product’s serial number below (located on product specs decal).
Serial No.______________________________________
After receiving the RA form, ship your Product to:
Vornado Air LLC
Attn: Warranty & Repair
415 E. 13th Street
Andover, KS 67002
This warranty does not apply to defects resulting from abuse of the
Product, modification, alteration, repair or service of the Product by
anyone other than Vornado, mishandling, improper maintenance,
commercial use of the Product, damages which occur in shipment or are
attributed to acts of God.
To assure proper handling, packages must be clearly marked with the RA
number. Packages not clearly marked with the RA number may be refused at the
receiving dock.
REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS
THE EXCLUSIVE REMEDY OF THE CONSUMER. VORNADO SHALL
NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL
DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY
ON THIS PRODUCT. EXCEPT TO THE EXTENT PROHIBITED BY
APPLICABLE LAW, ANY IMPLIED WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS
LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.
Please allow 1-2 weeks for repair and return of your Product after the
Product is received.
© 2011 Vornado Air LLC Andover, KS 67002
Specifications subject to change without notice. Vornado® is a trademark owned
by Vornado Air LLC. Designed, engineered and assembled in the U.S.A.
Some states do not allow the exclusion or limitation of incidental or
consequential damages, or allow limitations on how long an implied
warranty lasts, so the above limitations or exclusions may not apply to
you. This warranty gives you specific legal rights, and you may have
other rights that vary from state to state.
VORNADO CONSUMER SERVICES
For warranty or repair service, call 1-800-234-0604 or email
[email protected] to obtain a Return Authorization
(“RA”) form. Please have or include your Product’s model number and
serial number, as well as your name, address, city, state, zip code and
phone number when contacting Vornado for warranty service. You may
be required to provide the original sales receipt. For your records:
800.234.0604
8
English
Español
9
|