INSTRUCTION MANUAL
NETWORK COLOR CAMERA
N-CC2360
TABLE OF CONTENTS
1. SAFETY PRECAUTIONS .......................... 2
2. LIST OF INCLUDED
8. ADJUSTMENT ........................................... 9
9. ABOUT THE MODE SWITCH .................. 11
10. ABOUT THE CONTACT
COMPONENTS AND PARTS ............ 3
3. GENERAL DESCRIPTION ........................ 4
4. HANDLING PRECAUTIONS ..................... 4
5. NOMENCLATURE ..................................... 5
6. INSTALLATION ......................................... 6
INPUT/ OUTPUT TERMINAL ...... 12
11. SETTING INITIALIZATION ....................... 13
12. TROUBLESHOOTING .............................. 14
13. SPECIFICATIONS .................................... 15
System Requirements
7. CONNECTIONS
7.1. Connection Example ............................ 8
(for Software decoder) ................. 18
Thank you for purchasing TOA's Network Color Camera. Please carefully follow the instructions in this
manual to ensure long, trouble-free use of your equipment.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
CAUTION
When Installing the Unit
Avoid installing the unit in humid or dusty locations, in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric
shock.
•
Leave the installation of the unit to your TOA dealer because the installation requires expert experience and
skills. If the unit falls, this could cause personal injuries.
•
When the Unit is in Use
Do not hang down from the unit as this may cause it to fall down or drop, resulting in personal injury and/or
property damage.
•
CU version complies with Part 15 of the FCC Rules.
Note
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Modifications
Any modifications made to this device that are not approved by TOA Corporation may void the authority
granted to the user by the FCC to operate this equipment.
2. LIST OF INCLUDED COMPONENTS AND PARTS
Check to be sure that the following components and parts are contained in the package:
................................................................................
........................
Power conversion cable
CD-ROM ( Software Decoder: N-SD2000, Manuals (PDF))
1
1
1
1
1
..................................................
Network Color Camera Instruction Manual
........................................................................
Software license agreement
Network Camera System Installation Guide
................................................
Note
The CD-ROM contains Software Decoder, Software Decoder Instruction Manual, Setting Manual, Adobe
Reader, and DirectX.
3
3. GENERAL DESCRIPTION
The N-CC2360 Network Color Camera can be connected directly to a LAN (10BASE-T/100BASE-TX). Since it
can simultaneously transmit MPEG-4 and JPEG data, smooth moving images can be monitored and high-
definition still images monitored and recorded. The N-CC2360 can transmit bi-directional sub-band ADPCM or
PCM quality voice. Its power supply features PoE compatibility in addition to 24V AC or 24V DC operation,
permitting simplified wiring work and cable savings during construction by supplying power via the network.
The supplied software decoder permits the system to be remotely monitored and easily configured on a
personal computer. Since it is equipped with a Day-Night function that increases sensitivity by automatically
switching color images to monochrome under poor lighting conditions, and a 64x Electronic Sensitivity Boost
function as well as a Wide Dynamic function, the camera enables monitoring even in dark or backlight
locations. Camera functions can be easily set, and color and brightness remotely adjusted from distant
locations using a network browser.
4. HANDLING PRECAUTIONS
Do not direct the camera lens to the sun or strong lighting or light reflection. Exposure to direct sunlight
could cause the CCD's color filter to deteriorate, leading to image discoloration.
•
Do not give the camera a great shock or vibration, as this will damage the camera.
•
It is recommended that the camera be always used in locations where the ambient temperature ranges from
•
+
–10°C to 50°C (continuous active for operation at temperature below 0°C) and the humidity is under 90%
to ensure that no condensation is formed.
To clean, wipe with a dry soft cloth. Never use benzene, thinner or chemically processed towel as the
camera's plastic or other parts may be deformed or discolored.
•
•
•
•
When dust has settled on the camera's lens, lightly clean using a commercial camera blower or cleaning
paper.
Installing the LAN cables in close proximity to fluorescent lamps or other electrical appliances can
downgrade the picture quality. In such cases, change the wiring.
If there is a strong electric or magnetic field near the camera, such as television transmission antennas,
motors or transformers, this may distort or roll the monitor picture. In such cases, run the entire wiring route
through metal conduit tubing.
Shielded (STP) network cables must be used with this unit to ensure compliance with EMC standerds.
If the Day/Night mode is used, the subject may go out of focus when the display is switched between color
and B&W modes. In such cases, use a lens designed for visible light of up to the near-infrared region.
Install cables so as to prevent their damage and provide ample cable slack if they need to be stretched taut.
The IP address, subnet mask, and gateway IP address must be set.
•
•
•
•
•
•
•
Transmission to multiple receivers using the unicast function could result in a reduction in the frame rate.
When using the multicast function, the network must be compatible with the multicast system.
When a connection is established between the transmitter and multiple receivers, if the data rate requested
by each receiver differs, the transmission will be limited to the minimum set data rate.
In transmission streaming mode, data is constantly transmitted from camera to network even when no
communications are performed between the two.
•
•
•
Personal computers running Microsoft Windows XP are required when performing initial settings for the
network color camera.
TOA's software decoder does not support Macintosh or Unix operating systems.
• MPEG-4 visual patent portfolio license
With respect to a Licensee offering MPEG-4 Video Decoders and/or Encoders the following notice shall be
given:
THIS PRODUCT IS LICENSED UNDER THE MPEG-4 VISUAL PATENT PORTFOLIO LICENSE FOR THE
PERSONAL AND NON-COMMERCIAL USE OF A CONSUMER FOR (1) ENCODING VIDEO IN
COMPLIANCE WITH THE MPEG-4 VISUAL STANDARD (“MPEG-4 VIDEO”)AND/OR (2) DECODING
MPEG-4 VIDEO THAT WAS ENCODED BY A CONSUMER ENGAGED IN A PERSONAL AND NON-
COMMERCIAL ACTIVITY AND/OR WAS OBTAINED FROM A VIDEO PROVIDER LICENSE BY MPEG LA
TO PROVIDE MPEG-4 VIDEO. NO LICENSE IS GRANTED OR SHALL BE IMPLIED FOR ANY OTHER
USE. ADDITIONAL INFORMATION INCLUDING THAT RELATING TO PROMOTIONAL, INTERNAL AND
COMMERCIAL USES AND LICENSING MAY BE OBTAINED FROM MPEG LA,LLC.
SEE HTTP://WWW.MPEGLA.COM.
4
5. NOMENCLATURE
[
]
Top panel
7
[
]
[
]
[
]
N-CC2360 Rear panel
Side panel
Front panel
8
4
11
5
3
10/100M
AUDIO
OUT
MONITOR
OUT
LINK
/ACT
FD/COL
CONTACT
IN
OFF
ON
RDY BUSY ERR
INITIALIZE
OUT
F.ADJ
24V
2
1
ANTI-FLICKER
NC
2
RESET
1 2 C 1 2 C
24V
12
9
10
1
6
13
14
(1) Power Input Terminal [24 V AC, 24 V DC]
(6) Contact Input/Output Terminal
• Contact input terminal:
Connect this terminal to the 24 V AC or 24 V DC
power supply.
Used to receive alarm signals from sensors,
etc. Setting the terminal to a Day-Night function
places the camera in monochrome mode.
Note Do not connect 24 V AC or 24 V DC power
when using a PoE-compatible hub.
• Contact output terminal:
Connect external equipment to this terminal for
its control.
(2) Indicators [RDY BUSY ERR]
RDY (green): Remains lit during normal operation.
BUSY (yellow): Lights continuously during
communications.
(7) Back Focal Length Adjustment Ring Fixing
Screw
ERR (red): Lights when an error occurs.
Used to fix the back focal length adjustment
ring.
(3) Network Terminal [10BASE-T, 100BASE-TX]
Connect this terminal to a network.
• LINK/ACT indicator:
(8) Camera Mount
Lights when the network is correctly connected
and flashes while data is being transmitted or
received.
(9) Initialization Key
Returns camera settings to initial factory-preset
status.
• FD/COL indicator:
Lights continuously while the camera is opera-
ting in full-duplex mode, and remains unlit
while the camera is in half-duplex mode.
The indicator flashes when a data collision
occurs over the network.
(10) Reset Key
Restarts the camera.
(11) Lens Connector
Connect the connector of the lens to this
connector.
(4) Audio Output Terminal (RCA pin jack)
Outputs audio signals received via a network.
(12) Mode Setting Switch
Changes camera settings.
(5) Monitor Output Terminal (RCA pin jack)
Connect a monitor to this terminal.
(13) Back Focal Length Adjustment Ring
(14) Microphone
5
6. INSTALLATION
[Ceiling Mounting Example]
Ceiling surface
[Wall Mounting Example]
Camera mounting
bracket (optional)
Lock lever
Camera mounting
bracket (optional)
Pedestal
Camera mount
Camera mount
Pedestal
Camera mounting
Lock lever
bracket (optional)
Install the unit only in a location that can structurally support the weight of the
unit and the mounting bracket. Doing otherwise may result in the unit falling
down and causing personal injury and/or property damage.
WARNING
1. Select the lens type on the Camera menu screen.
Select the lens for the best possible picture reproduction. (Refer to Setup Manual)
Lens type
Camera Menu
DC input type, Automatic aperture control lens
Manual-iris or fixed iris lens
DC
Manual
Notes
Video lens is also displayed on the camera menu, however it cannot be used with the N-CC2360 camera.
•
•
When using the flicker-reduction function outdoors or under the fluorescent lighting, select the auto-iris lens.
When the manual-iris lens is selected, the flicker-reduction function cannot be used.
Lens connector
Connector
2. Attach the lens to the camera.
•
from the lens
Tighten the lens fully onto a camera's lens mount
to secure it.
Lens
Insert the connector from the lens into the lens
connector.
•
OFF
ON
INITIALIZE
F.ADJ
ANTI-FLICKER
NC
RESET
Lens connector
Lens connector
pin No.
DC input type
LENS
2
4
1
3
–
+
+
–
Damping coil
Damping coil
Driving coil
Driving coil
1
2
3
4
6
Notes
6mm or less
To avoid damaging the internal sections of the camera's lens mount, be sure
that the lens flange is 6 mm or less thick as illustrated on the right.
C-mount lenses must be used in conjunction with the Lens Mounting Adapter
CF-5 (optional).
•
•
Lens
3. Mount the optional Camera Mounting Bracket to the ceiling or wall.
The bracket must be fixed securely using an electrical box and screws supplied with the bracket. When
securing, be sure to run the LAN cable through the hole in the bracket.
4. Rotating the bracket's pedestal, fully insert it into the threaded hole in the camera mount.
Note
The mount can be attached on either the top or bottom panel of the camera, Change the position
depending on the installation site. (factory default: The camera mount is attached on the top panel.)
5. Determine the camera direction and fix it.
Set the camera's direction, then fix the camera by rotating the lock lever on the Camera Mounting Bracket.
7
7. CONNECTIONS
7.1. Connection Example
By connecting a network video receiver and PC to a hub and performing each equipment settings at the PC,
camera images can be viewed at the monitor. Installing the supplied software decoder in the PC permits
camera settings to be performed and camera images to be viewed at the pc with the software decoder
installed. When connecting the N-CC2360 network color camera to the hub, use CAT 5 or greater straight
cable fitted with RJ45 connectors.
For each equipment setting, refer to the Setup Manual.
100BASE-TX/1000BASE-T
Software Decorder
Network
N-SD2000
Video Receiver
10BASE-T/
N-VR2010
Video output Video input
100BASE-TX
PoE compatible HUB
DC-IN
8
7
6
5
4
3
2
1
Audio input
Audio output
AC Mains
Monitor
10BASE-T/
100BASE-TX
Monitor output terminal
10/100M PoE
AUDIO
OUT
MONITOR
OUT
Network
LINK
/ACT
Note
FD/COL
Color Camera
Connect the output terminal to the monitor
when adjusting the camera.
CONTACT
IN
RDY BUSY ERR
N-CC2360
OUT
24V
2
1
1 2 C 1 2 C
24V
Contact input/output terminal
Refer to p. 12
BNC plug (optional)
Pin plug
24 V AC or 24 V DC
Applicable cables. Solid cable: AWG 26
-
16
Stranded cable: AWG 22
-
16
Notes
• Do not connect the 24V AC or 24V DC power when using a PoE-compatible hub since the power is supplied
from the hub.
• Connect the 24V AC or 24V DC power when not using a PoE-compatible hub since no power is supplied
from the hub.
• The distance between camera and hub must be shorter than 100 meters using CAT 5 or greater cable.
• Shielded (STP) network cables must be used with this unit to ensure compliance with EMC standards.
8
8. ADJUSTMENT
1. The RDY indicator lights when the power is supplied to the network camera.
2. Connect the monitor output terminal to the monitor so that the picture may be displayed on the monitor.
3. Set the Flicker-reduction switch of the mode switch to "ON" position if flicker is annoying.
Flickering of the picture may interfere with the view under fluorescent lamps in the area where power
frequency is 50 Hz (CU) or 60 Hz (PL). In such cases, set the Flicker-reduction switch to "ON" position, and
the image free from flickering can be obtained.
Note
Setting the Flicker-reduction switch to "ON" makes the sensitivity lower than when set to "OFF." Set to the
"OFF" position when flicker is not annoying or when the camera is used in locations with poor lighting
conditions.
4. Determine the camera orientation.
Loosen the lock lever on the Camera Mounting Bracket, set the camera to the desired direction, then
securely fix the camera by rotating the lock lever on the bracket.
5. Adjust the angle of view with the zoom ring and focus on with the focal ring to get the best possible picture
reproduction.
When focusing
•
The object that was brought into focus in bright locations could be out of focus in dark conditions. In such
cases, focus the lens after turning the Focus adjustment switch of mode switch to "ON" position.
Note: After focus adjustment completion, turn the switch to "OFF" position.
Adjusting back focal length
•
When the distance to an object is shorter than the lens' shortest focusing distance, if the object is out of
focus, adjust the camera with the below procedures.
(1) Attach a lens to the camera.
(2) Loosen the back focal length adjustment ring fixing screw.
(3) Rotating the back focal length adjustment ring, adjust it to the optimum position.
(4) Retighten the back focal length adjustment ring fixing screw.
Ceiling surface
Back focal length
Camera Mounting
Bracket (optional)
adjustment ring fixing screw
Lock lever
Zoom ring
Focal ring
Back focal length
adjustment ring
9
6. Adjust the iris level
When using the DC input type lens
•
Adjust the iris level on the Camera menu screen's "IRIS" item.
6-1 Check to confirm that Camera menu setting items are selected as follows.
Lens selection:
"DC"
(
)
Backlight compensation: "OFF" factory default: OFF
6-2 Moving the bar toward "HIGH" side makes the image brighter, and moving it toward "LOW" side makes
the image darker.
6-3 Set backlight compensation of a Camera menu screen according to the object condition.
Note: For the Camera Menu setting, refer to the Setup Manual.
10
9. ABOUT THE MODE SWITCH
Set each switch to the position that provides the best picture reproduction.
[
]
N-CC2360
OFF
ON
Focus adjustment switch
Flicker-reduction switch
F.ADJ
OFF
ON
ANTI
-FLICKER
INITIALIZE
F.ADJ
ANTI-FLICKER
NC
Not used.
NC
RESET
(
)
Mode switch factory default
Mode switch
• Focus adjustment switch
Set this switch when adjusting the focus of a lens. This setting provides the same effect as when using an
(
)
ND filter.
Normal:
After focus adjustment completion, turn the switch to "OFF" position. Normally, use
this mode.
OFF
ON
(
Adjustment At the time of Adjustment :
)
Set the switch when focusing the lens. The object that was brought into focus in
bright locations could be out of focus in dark conditions. In such cases, turn the
Focus adjustment switch to "ON" position only when adjusting focus.
OFF
ON
Note
When the Focus adjustment switch is set to the "ON" position, the color of the
screen may change periodically if the camera is used under fluorescent lighting.
Further, the screen may flicker in areas where the electrical frequency is 50 Hz.
• Flicker-reduction switch
Set the switch when flicker is annoying.
Normal:
Normally, use this mode.
OFF
OFF
ON
ON
Flicker-reduction:
Flickering of the picture may interfere with the view under fluorescent lamps in the
area where the electrical frequency is 50 Hz (CU) or 60 Hz (PL). In such cases, set
the Flicker-reduction switch to "ON" position, and the image free from flickering can
be obtained.
Note
Setting the Flicker-reduction switch to "ON" makes the sensitivity lower than when
set to "OFF." Set to the "OFF" position when flicker is not annoying or when the
camera is used in locations with poor lighting conditions.
11
10. ABOUT THE CONTACT INPUT/ OUTPUT TERMINAL
• Contact Input
There are two no-voltage contact inputs for connection of sensor trigger signals, etc. A contact can be
automatically established between the transmitter and the network video receiver or network digital recorder
when a signal enters the contact.
Setting the contact input to Day & Night mode forcibly, shorting (making) the Day/Night input terminal forcibly
switches the display to B&W mode, which increases the camera’s sensitivity. For details, refer to the Setup
Manual.
Note
The Day & Night function can also be set using the camera menu. If "Normal," "Motion," or "Color" has been
selected for the Day & Night function, the display could repetitively switch between color and black-and-white
modes when the camera is used under phototransmitter. In such cases, select "Day & Night" in the "Contact
Input" settings, and synchronize the phototransmitter power supply with the switch to black-and-white mode.
The display mode changes as follows if the Contact Input has been set to "NO" (Normally Open):
Infrared phototransmitter power "ON" : B&W mode (close)
Infrared phototransmitter power "OFF" : Color mode (open)
• Contact Output
There are two contact outputs, allowing external connected device control and contact bridging between video
network system devices. For details, refer to the Setup Manual.
1 2 3 4 5 6
10/100M
AUDIO
OUT
MONITOR
OUT
LINK
/ACT
FD/COL
Day/ Night
Contact name
Contact input 1
Contact input 2
COM
Contact output 1
Contact output 2
COM
No. Terminal Name
CONTACT
IN
RDY BUSY ERR
OUT
Select Contact input 1
or Contact input 2.
COM
1
2
3
4
5
6
IN 1
IN 2
C
24V
2
1
1 2 C 1 2 C
24V
OUT 1
OUT 2
C
Color: Open
Black & white: Closed
IN
GND
The figure shows that IN1 Contact
Input/Output terminal is set to
Day/Night Input terminal position.
Applicable cables
Solid cable: AWG28 (ø 0.32) – AWG22 (ø 0.65)
Stranded cable: AWG28 (0.08 mm2 ) – AWG22 (0.32 mm2 )
Note: Strip the cable sheath approximately 10 mm, then insert the cable while pushing down the button on the
terminal with a screwdriver.
12
11. SETTING INITIALIZATION
Network settings can be reset to their factory defaults.
1. Either press the Reset key or switch on the power again while holding down the INITIALIZE key.
2. Continue to press the INITIALIZE key until the Ready indicator has switched from flashing to steady-on
mode.
Note
To return camera settings other than those used for network settings to default conditions, use the camera
menu. For the camera menu settings, refer to the Setup Manual.
13
12. TROUBLESHOOTING
Remedy
Symptom
Possible cause
Supply power independently to the
Camera.
Camera does not start.
(RDY does not light.)
Power is not supplied.
[ When using a PoE-compatible hub
for power supply ]
•Camera not connected to the PoE-
compatible hub.
•PoE-compatible hub’s PoE function
is not made valid.
•Camera is connected to the PoE-
compatible hub’s port not supporting
PoE.
•Power requirement exceeds the
PoE-compatible hub’s supply
capability.
[ When using 24V AC or 24V DC for
power supply ]
•Incorrect terminal connections.
Cable is not correctly connected to
the Camera’s network terminal.
Confirm that the cable type (category,
null modem or straight) is appropriate
for the connected port, then connect
correctly.
LINK/ACT does not
light.
If the rough noise is annoying and
distracting, lower the AGC level.
Rough noise appears
when the subject be-
comes dark at night.
After image appears
when the subject be-
comes dark at night.
Mode frequently swi-
tches between color
and black-and-white.
Camera's AGC function has been
activated and noise is amplified
Camera's Slow Shutter function has If the after image is annoying and
been activated.
distracting, decrease the Slow Shutter
magnification.
Phototransmitter is operating.
If an phototransmitter is used, take any
one of the following actions:
If a phototransmitter is used, connect
•
it to the external Day & Night selection
input so that the Day & Night function
is operated as the phototransmitter is
activated.
Manually set the Day & Night function
•
to ON using the software decoder
while the infrared projector remains lit.
Reduce infrared floodlighting amount
•
by changing the infrared projector's
angle.
14
13. SPECIFICATIONS
[N-CC2360 CU]
* 0 dB = 1V
24 V AC, 50/60 Hz or 24 V DC or PoE (IEEE802.3af)
13 W (at 24 V AC), (8 W: PoE, 350mA: 24 V DC)
Power Source
Power Consumption
(Solid cable: ø 0.4– ø 1.2 mm (AWG 26 – 16),
Power Terminal
Screwless connector
Stranded cable: 0.3–1.25 mm2 (AWG 22 – 16)
VBS 1.0 V(p-p), 75 Ω, RCA pin jack, NTSC
Omnidirectional, electret condenser microphone
Monitor Output
Microphone
1channel, –10
*
dB , low impedance,
unbalanced, RCA pin jack
Audio Output
Contact Input
2 channels (Color/B&W Switching Input included), no-voltage contact input,
open voltage: 9 V DC, short-circuit current: Under 10 mA,
loop resistance: Under 200 Ω, screwless connector
2 channels, open collector output, withstand voltage: 30 V DC,
control current: 50 mA screwless connector
Contact Output
Camera
1/ 3 type IT-CCD
Image Device
( ) ( ) (
768 H x 494 V 380,000 pixels
)
Number of Effective Pixels
Scanning System
Scanning Frequency
Synchronizing System
Minimum Required
Illumination
2:1 interlace
Horizontal: 15.734 kHz , Vertical: 59.94 Hz
Internal
(
)
(
) (
) (
) (
)
0.5 lx 50 IRE , 0.1 lx 20 IRE F1.0 sensitivity up: OFF color mode
0.01 lx (F1.0) (sensitivity up: ON) (B&W mode, incandescent lamp)
1: 2000 (F1.4 – 63)
Automatic Electric
Shutter Range
(backlight compensation:
)
wide dynamic: ON
46 dB
Dynamic Range
Backlight Compensation
Shutter Speed
WIDE DYNAMIC/ ON/ OFF
1/60, 1/100, 1/125, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000
Auto/ Fixed/ OFF
AGC
OFF, 2, 4, 6, 8, 10, 16, 24, 32, 64 times
ATW/ AWB/ Manual
Sensitivity Up
White Balance Mode
Lens Mount
CS mount
DC input type (4 pin connector)
Up to 16 characters (alphanumeric and symbols)
Auto-Iris Lens Output
Character Display
Other Functions
(
),
Privacy masking (up to 4), Electronic Zoom 2x Horizontal/Vertical reverse,
(
)
Flickering reduction (DIP switch), Focus adjustment switch DIP switch ,
(
Chroma level: Normal/Manual MIN
)
MAX ,
-
(
Enhancer: Normal/Manual soft
)
sharp
-
Network
10BASE-T/100BASE-TX, Auto-Nego/Manual: RJ45 connector
TCP, UDP, SIP, RTP, IGMP, HTTP, ARP,DHCP, DNS, SNTP
MPEG-4: D1 (720 x 480), Half D1 (720 x 240), QVGA (320 x 240)
Network I/F
Network Protocol
Video Compression/
Resolution
JPEG:
D1 (720 x 480), Half D1 (720 x 240), VGA (640 x 480)
QVGA (320 x 240), QQVGA (160 x 120)
MPEG-4 (D1, max. 30 fps) + JPEG (D1, max. 5 fps)
Sub-band ADPCM, PCM (non-compression)
Frame Rate
Audio Compression/
Decompression
8 kHz, 32 kHz
Audio Sampling Frequency
15
Network
Image Transfer Rate
Simultaneous Connected 5 (MPEG-4: 4, JPEG: 1)
MPEG-4: max. 4 Mbps
Number
In streaming mode: No limit (MPEG-4 only)
Password authentication, Motion detection
Other Functions
Operating Temperature
–
+
10°C to 50°C (continuously active for operation at temperature below 0°C)
14°F to 122°F (continuously active for operation at temperature below 32°F)
(
Under 90 % RH no condensation
)
Operating Humidity
Application
Finish
Indoor use
Case: Surface-treated steel plate, sand gray, paint
(
)
( )
( )
"
Dimensions
Weight
69.3 W x 64.8 H x 157.3 D mm (2.73 x 2.55" x 6.19")
670 g (1.48 lb)
Note: The design and specification are subject to change without notice for improvement.
16
[N-CC2360 PL]
* 0 dB = 1V
24 V AC, 50/60 Hz or 24 V DC or PoE (IEEE802.3af)
13 W (at 24 V AC), (8 W: PoE, 350mA: 24 V DC)
Power Source
Power Consumption
Power Terminal
(Solid cable: ø 0.4– ø 1.2 mm (AWG 26 – 16),
Screwless connector
Stranded cable: 0.3–1.25 mm2 (AWG 22 – 16)
VBS 1.0 V(p-p), 75 Ω, RCA pin jack, PAL
Omnidirectional, electret condenser microphone
Monitor Output
Microphone
1channel, –10
*
dB , low impedance,
unbalanced, RCA pin jack
Audio Output
Contact Input
2 channels (Color/B&W Switching Input included), no-voltage contact input,
open voltage: 9 V DC, short-circuit current: Under 10 mA,
loop resistance: Under 200 Ω, screwless connector
2 channels, open collector output, withstand voltage: 30 V DC,
control current: 50 mA screwless connector
Contact Output
Camera
1/ 3 type IT-CCD
Image Device
( ) ( ) (
768 H x 582 V 440,000 pixels
)
Number of Effective Pixels
Scanning System
Scanning Frequency
Synchronizing System
Minimum Required
Illumination
2:1 interlace
Horizontal: 15.734 kHz , Vertical: 50.00 Hz
Internal
(
)
(
) (
) (
) (
)
0.5 lx 350 mV , 0.1 lx 140 mV F1.0 sensitivity up: OFF color mode
0.01 lx (F1.0) (sensitivity up: ON) (B&W mode, incandescent lamp)
1:2400 (F1.4 – 63)
Automatic Electric
Shutter Range
(backlight compensation:
)
wide dynamic: ON
46 dB
Dynamic Range
Backlight Compensation
Shutter Speed
WIDE DYNAMIC/ ON/ OFF
1/50, 1/100, 1/125, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000
Auto/ Fixed/ OFF
AGC
OFF, 2, 4, 6, 8, 10, 16, 24, 32, 64 times
ATW/ AWB/ Manual
Sensitivity Up
White Balance Mode
Lens Mount
CS mount
DC input type (4 pin connector)
Up to 16 characters (alphanumeric and symbols)
Auto-Iris Lens Output
Character Display
Other Functions
(
),
Privacy masking (up to 4), Electronic Zoom 2x Horizontal/Vertical reverse,
(
)
Flickering reduction (DIP switch), Focus adjustment switch DIP switch ,
(
Chroma level: Normal/Manual MIN
)
MAX ,
-
(
Enhancer: Normal/Manual soft
)
sharp
-
Network
10BASE-T/100BASE-TX, Auto-Nego/Manual: RJ45 connector
TCP, UDP, SIP, RTP, IGMP, HTTP, ARP,DHCP, DNS, SNTP
MPEG-4: D1 (720 x 576), Half D1 (720 x 288), CIF (352 x 288)
Network I/F
Network Protocol
Video Compression/
Resolution
JPEG:
D1 (720 x 576), Half D1 (720 x 288), CIF (352 x 288),
VGA (640 x 480), QVGA (320 x 240), QQVGA (160 x 120)
MPEG-4 (D1, max. 25 fps) + JPEG (D1, max. 5 fps)
Sub-band ADPCM, PCM (non-compression)
Frame Rate
Audio Compression/
Decompression
8 kHz, 32 kHz
Audio Sampling Frequency
17
Network
Image Transfer Rate
Simultaneous Connected 5 (MPEG-4: 4, JPEG: 1)
MPEG-4: max. 4 Mbps
Number
In streaming mode: No limit (MPEG-4 only)
Password authentication, Motion detection
Other Functions
Operating Temperature
–
+
10°C to 50°C (continuously active for operation at temperature below 0°C)
14°F to 122°F (continuously active for operation at temperature below 32°F)
(
Under 90 % RH no condensation
)
Operating Humidity
Application
Finish
Indoor use
Case: Surface-treated steel plate, sand gray, paint
(
)
( )
( )
"
Dimensions
Weight
69.3 W x 64.8 H x 157.3 D mm (2.73 x 2.55" x 6.19")
670 g (1.48 lb)
Note: The design and specification are subject to change without notice for improvement.
• System Requirements (for Software decoder)
Personal Computer
Main Specifications
PC/AT compatible
CPU:
Pentium 4, over 3 GHz
Over 512 MB
Memory:
Display adapter: XGA (1024 x 768 pixels), Intel Chipset (Recommended)
Usable on DirectX 9.0a or later
Sound controller: Usable over DirectX 9.0a or later
Network adapter: Over 100BASE-TX
OS
Windows XP Professional
Required Web Browser Internet Explorer 6.0 or later
Notes
• Pentium and Intel are trademark of Intel Corporation.
• Windows is a trademark of Microsoft Corporation.
18
19
|