Renesas Computer Hardware FP 128 User Guide

H8S/2636 Series  
FP-128  
User System Interface Cable  
(HS2636ECH61H)  
for E6000 Emulator  
User’s Manual  
HS2636ECH61HE(B)  
 
Preface  
Thank you for purchasing this user system interface cable (HS2636ECH61H) for the Renesas’s  
original microcomputer H8S/2636 series.  
The HS2636ECH61H is a user system interface cable that connects an H8S/2636 and H8S/2646  
series E6000 emulator (HS2646EPI61H; hereinafter referred to as the emulator) to the IC socket for  
a FP-128 package for the H8S/2636 series MCU on the user system.  
i
 
Contents  
ii  
 
Section 1 Configuration  
CAUTION  
Use an NQPACK128RD socket (manufactured by  
Tokyo Eletech Corporation) for the FP-128 package  
IC socket on the user system.  
Figure 1 shows the configuration of the HS2636ECH61H user system interface cable for the  
FP-128 package.  
1
 
 
Figure 1 HS2636ECH61H User System Interface Cable  
2
 
Table 1 lists the HS2636ECH61H components. Please make sure you have all of these components  
when unpacking.  
Table 1  
HS2636ECH61H Components  
No. Component  
Quantity  
Remarks  
1
2
3
4
5
6
7
8
9
Cable body  
1
1
1
1
4
4
3
1
1
Flat cable  
Cable head  
IC socket  
For the FP-128 package  
Socket cover  
Screws (M2 x 10 mm)  
Screws (M2 x 6 mm)  
Guide pins  
For installing anFP-128 packaged MCU  
For fastening cable head  
For installing an FP-128 packaged MCU  
For determining the IC socket location  
For tightening screws  
Screwdriver  
Documentation  
User’s manual for HS2636ECH61H (this manual)  
3
 
Section 2 Connection Procedures  
2.1  
Connecting User System Interface Cable to Emulator Station  
WARNING  
Observe the precautions listed below. Failure to do so  
will result in a FIRE HAZARD and will damage the user  
system and the emulator product or will result in  
PERSONAL INJURY. The USER PROGRAM will be  
LOST.  
1. Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before  
connecting, make sure that pin 1 on both sides are  
correctly aligned.  
2. The user system interface cable dedicated to the  
emulator must be used.  
To connect the cable body to the emulator station, follow the instructions below.  
1. Make sure the user system and emulator station are turned off.  
CAUTION  
When connecting or removing the user system interface  
cable, apply force only in the direction suitable for  
connection or removal, while making sure not to bend or  
twist the cable or connectors. Otherwise, the connectors will  
be damaged.  
2. After making sure the direction of the cable body connector is correct, firmly insert the cable  
body connector into the emulator station socket (figure 2).  
4
 
 
Figure 2 Connecting User System Interface Cable to Emulator Station  
5
 
2.2  
Connecting User System Interface Cable to User System  
WARNING  
Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before  
connecting, make sure that pin 1 on both sides are correctly  
aligned. Failure to do so will result in a FIRE HAZARD and  
will damage the user system and the emulator product or  
will result in PERSONAL INJURY. The USER PROGRAM will  
be LOST.  
To connect the cable head to the user system, follow the instructions below.  
2.2.1 Installing IC Socket  
After checking the location of pin 1 on the IC socket, determine where to install the IC socket by  
using the guide pins provided as shown in figure 3. Apply epoxy resin adhesive to the end of the  
four projections at the bottom of the IC socket, and fasten it to the user system before soldering.  
6
 
 
Guide pins  
Pin 1  
4 projections to apply  
epoxy resin adhesive to  
Bottom view of IC soket  
User system  
Figure 3 Location Setting of IC Socket  
2.2.2  
Soldering IC Socket  
After fastening, solder the IC socket for an FP-128 package to the user system. Be sure to  
completely solder the leads so that the solder slops gently over the leads and forms solder fillets.  
(Use slightly more solder than the MCU.)  
2.2.3  
Inserting Cable Head  
CAUTION  
Check the location of pin 1 before inserting.  
Align pin 1 on the IC socket for an FP-128 package on the user system with pin 1 on the user system  
interface cable head, and insert the user system interface cable head into the IC socket on the user  
system, as shown in figure 4.  
7
 
 
2.2.4  
Fastening Cable Head  
CAUTION  
1. Use the screwdriber provided for tightening screws.  
2. The tightening torque must be 0.054 N•m or less.  
If the applied torque cannot be accurately measured,  
stop tightening when the force required to turn the screw  
becomes significantly greater than that needed when first  
tightening. If a screw is tightened too much, the screw  
head may break or an IC socket contact error may be  
caused by a crack in the IC socket solder.  
3. If the emulator does not operate correctly, cracks might  
have occurred in the solder. Check conduction with  
a tester and re-solder the IC socket if necessary.  
Fasten the user system interface cable head to the IC socket for an FP-128 package on the user  
system with the four screws (M2 x 10 mm) provided. Each screw should be tightened a little at a  
time, alternating between screws on opposing corners. Take special care, such as manually securing  
the IC socket soldered area, to prevent the soldered IC socket from being damaged by  
overtightening the screws or twisting the components.  
8
 
 
Figure 4 Connecting User System Interface Cable to User System  
9
 
2.2.5  
Fastening Cable Body  
Connect the cable body to the cable head.  
Cable body  
Removing  
Push the remove jig  
Remove jig  
Cable head  
User system  
Figure 5 Fastening Cable Body  
10  
 
 
2.3  
Recommended Dimensions for User System Mount Pad  
Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with  
an IC socket for an FP-128 package (NQPACK128RD: manufactured by Tokyo Eletech  
Corporation). Note that the dimensions in figure 6 are somewhat different from those of the actual  
chip's mount pad.  
17.00 ± 0.15  
8.50  
6.00  
3-1.00  
2.00 ± 0.10  
0.50  
0.25  
Unit: mm  
Tolerance: ± 0.10 mm  
Figure 6 Recommended Dimensions for Mount Pad  
11  
 
 
2.4  
Dimensions for User System Interface Cable Head  
The dimensions for the user system interface cable head are shown in figure 7.  
Figure 7 Dimensions for User System Interface Cable Head  
12  
 
 
2.5  
Resulting Dimensions after Connecting User System Interface Cable  
The resulting dimensions, after connecting the user system interface cable head to the user system,  
are shown in figure 8.  
Figure 8 Resulting Dimensions after Connecting User System Interface Cable  
13  
 
 
Section 3 Installing the MCU to the User System  
CAUTION  
1. Check the location of pin 1 before inserting.  
2. Use the screwdriver provided for tightening screws.  
3. The tightening torque must be 0.054 N•m or less.  
If the applied torque cannot be accurately measured,  
stop tightening when the force required to turn the screw  
becomes significantly greater than that needed when first  
tightening. If a screw is tightened too much, the screw  
head may break or an IC socket contact error may be  
caused by a crack in the IC socket solder.  
4. If the MCU does not operate correctly, cracks might have  
occurred in the solder. Check conduction with a tester  
and re-solder the IC socket if necessary.  
Check the location of pin 1 before inserting the MCU into the IC socket on the user system, as  
shown in figure 9. After inserting the MCU, fasten the socket cover with the provided four screws  
(M2 x 6 mm). Take special care, such as manually securing the IC socket soldered area, to prevent  
the IC socket from being damaged by overtightening the screws or twisting the components.  
14  
 
 
Figure 9 Installing MCU to User System  
15  
 
Section 4 Verifying Operation  
1. When using the E6000 emulator for the H8S/2636 series, turn on the emulator according to the  
procedures described in the H8S Series E6000 Emulator User's Manual (HS2000EPI61HE).  
2. Verify the user system interface cable connections by accessing the external memory and ports  
to check the bus states of the pins with the MEMORY_FILL command (emulator command). If  
an error is detected, recheck the soldered IC socket and the location of pin 1.  
3. The emulator connected to this user system interface cable supports two kinds of clock sources  
as the MCU clock: an emulator internal clock and an external clock on the user system. For  
details, refer to the Emulator Supplementory Information (HS2646EPI61HE).  
To use the emulator internal clock  
Select the clock in the emulator station as the system clock (φ), by using the CLOCK  
command (emulator command).  
To use the external clock on the user system  
Select the target clock t or t2 as the system clock (φ), by using the CLOCK command  
(emulator command). Supply the external clock from the user system to the emulator by  
inputting the external clock from the EXTAL on the cable head or connecting a crystal  
oscillator to the EXTAL and XTAL terminals. For details, refer to section 21, Clock Pulse  
Generator, in the H8S/2636 F-ZTAT™ Hardware Manual.  
Figure 10 shows the oscillator circuit on the user system interface cable.  
R1 1 M  
HCU04  
HCU04  
To E6000  
emulator  
HCU04  
R2 270  
EXTAL XTAL  
Figure 10 Clock Oscillator Circuits  
16  
 
 
Section 5 Notice  
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable  
head before inserting the cable head into the user system IC socket.  
2. The dimensions of the recommended mount pad for the user system IC socket are different from  
those of the MCU.  
3. This user system interface cable is specifically designed for the HS2646EPI61H emulator. Do  
not use this cable with any other emulator station.  
4. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the  
user system interface cable.  
5. While the emulator station is connected to the user system with the user system interface cable,  
force must not be applied to the cable head. Place the emulator station, user system interface  
cable, and user system as shown in the example in figure 11.  
Figure 11 User System Interface Cable Location Example  
17  
 
 
6. The P1 jumper socket is used for testing. Do not remove the inserted jumper pin.  
Figure 12 P1 Jumper Socket  
18  
 

Q Logic Switch 59021 05 B User Guide
Radica Games Games 20Q User Guide
Radica Games Video Games 71008 User Guide
Radio Shack Radar Detector 22 1695 User Guide
RCA Stereo Amplifier RTD250 User Guide
Revox Speaker Resound L 120 User Guide
Roland Guitar G 33 User Guide
Rosewill Power Supply RV380 2 FRB S User Guide
Ryobi Saw SS180 User Guide
Sanyo Rice Cooker EC 503 User Guide