Installation and Assembly:
24" Wall Plate Accessory
Model: DS-VL-H024
Maximum Load Capacity: 350 lb (158.8 kg)
3215 W. North Ave. • Melrose Park, IL 60160 • (800) 729-0307 or (708) 865-8870 • Fax: (708) 865-2941 • www.peerlessmounts.com
ISSUED: 06-04-10 SHEET #: 120-9084-1
Before you begin, make sure all parts shown are included with your product.
PARTS LIST
A
Description
Qty.
1
8
4
2
Part #
145-1140
510-1079
590-0320
024-1045
560-1727
5S1-015-C03
A wall plate
B M4 x 12 mm socket pin serrated washer head screw
C 8 mm concrete anchor
D wall plate connector
E 18" 4 mm allen wrench
F # 14 x 2.5 hex head wood screw
1
4
Some parts may appear slightly different than illustrated.
B
C
D
E
F
Installing Additional Wall Plates (optional)
When installing additional wall plates (sold separately) , attach two wall plate connectors (D) on either end of wall
plate (A) and fasten with eight M4 x 12 serrated washer head socket pin screws (B) as shown below.
1
Skip to step 2 on page 5 for
installation to solid concrete or
cinder block walls.
B
D
A
BACK VIEW
ISSUED: 06-04-10 SHEET #: 120-9084-1
3 of 6
Installation to Double Wood Stud Wall
WARNING
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder
is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Install-
ers are responsible to provide hardware for other types of mounting situations.
Wall plate (A) can be mounted to four studs that are 16" apart. Use a stud finder to locate the edges of the studs.
Use of an edge-to-edge stud finder is highly recommended. Based on their edges, draw a vertical line down each
stud’s center. Place wall plate on wall as a template. Level plate, and mark the center of the four mounting holes.
Make sure that the mounting holes are on the stud center lines. Drill four 5/32" (4 mm) dia. holes 2.5" (65 mm)
deep. Make sure that the wall plate is level, secure it using four #14 x 2.5" wood screws (F) as shown in figure 2.2.
2
STUD
A
fig. 2.1
A
F
fig. 2.2
ISSUED: 06-04-10 SHEET #: 120-9084-1
4 of 6
Installation to Solid Concrete or Cinder Block
WARNING
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to
avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-
ware and components.
Make sure that wall plate (A) is level, use it as a
2
template to mark four mounting holes. Drill four
5/16" (8 mm) dia. holes to a minimum depth of 2.5"
(64 mm). Insert anchors (C) in holes flush with wall
as shown (right). Place wall plate over anchors and
secure with #14 x 2.5" screws (F). Level, then tighten
all fasteners.
concrete
surface
1
C
Drill holes and insert anchors (C).
A
2
WARNING
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
F
C
Place plate (A) over anchors (C) and secure with screws (F).
3
• Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
• Always attach concrete anchors directly to load-
bearing concrete.
Tighten all fasteners.
• Never attach concrete anchors to concrete covered
with plaster, drywall, or other finishing material.
If mounting to concrete surfaces covered with
a finishing surface is unavoidable, the finishing
surface must be counterbored as shown below.
Be sure concrete anchors do not pull away from
concrete when tightening screws. If plaster/drywall
is thicker than 5/8", custom fasteners must be
supplied by installer.
solid concrete
cinder block
C
INCORRECT
CORRECT
concrete
concrete
wall
plate
wall
plate
plaster/
drywall
plaster/
drywall
A
F
ISSUED: 06-04-10 SHEET #: 120-9084-1
5 of 6
Installing Multiple Wall Plates and Screens (Optional)
Install adapter brackets (sold separately) to screens using adapter bracket instructions.
Multiple wall plates and adapter brackets (sold separately) can be used to create multiple screen displays.
3
WALL PLATE MAY APPEAR
DIFFERENT THAN ILLUSTRATED
ACC-DSV240
(SOLD SEPARATELY)
ISSUED: 06-04-10 SHEET #: 120-9084-1
6 of 6
© 2010, Peerless Industries, Inc. All rights reserved.
All other brand and product names are trademarks or registered trademarks of their respective owners.
|