QS200
Handheld Scanner
Programming Manual
v 2.1
TABLE OF CONTENTS
Introduction
Flow Chart
1
Interfaces
2
On/Off Symbologies
Code 39
3
7
Codabar/NW7
Interleaved 2/5
Standard 2/5
8
9
11
12
13
14
15
16
17
20
21
23
24
25
27
Matrix 2/5
EAN-13/EAN-8
UPC-A/UPC-E
CHINESE POSTAL 2/5
Reading Modes
General Parameters
Keyboard Parameters
Terminal Type
Function Key Setting
Function Key Table
Function Key Labels
Languages
i
RS232 Parameters
CCD Wand Emulation
OCIA Types
28
31
32
33
34
36
38
39
40
Magnetic Setting
Code Mark
Truncate Digits
ASCII Table
Hexadecimal Labels
Pinout Assignments
Notes:
1. Options marked by { } are
only available for some models.
2. Factory default values are
indicated by
.
3. All references to numbers in this
menu are in Decimal, but you
MUST input it as Hexadecimal.
Ii
INTRODUCTION
Bar Code devices provide an
accurate, easy, and fast
method of data entry and data
storage for computerized
information systems.
The products we are offering
now can be integrated into any
host computer system by the
following ways:
Keyboard emulation
Wand emulation
RS-232C serial asynchronous
Dual RS-232C
RS-422
RS-485
Parallel
OCIA
OTHERS
All the operating parameters
are programmed by bar code
programming menu and stored
in non-volatile RAM which
can retain the settings
after power is turned off.
For the functions which are
not listed in this menu,
please consult your supplier
for more details.
*All rights reserved, including
those to reprint this manual.
-1- FLOW CHART
START OF CONFIGURATION
ꢀꢁꢂꢃꢄꢀ
SELECT INTERFACES
SELECT SYMBOLOGIES
OPERATION PARAMETERS
SET FACTORY DEFAULTS **
ꢀꢅꢆꢇ ꢀ
ABORT CONFIGURATION *
ꢀꢆꢈꢉ ꢀ
END OF CONFIGURATION **
ꢀꢊꢋꢉ ꢀ
SHOW VERSION
ꢀꢅꢌꢉ ꢀ
*
Reject new settings & end.
** Accept new settings & end.
INTERFACES - 2 -
ꢀꢍ ꢎꢀꢏ
KEYBOARD
ꢀꢍ ꢐꢀꢏ
RS232C
ꢀꢍ ꢑꢀꢏ
CCD WAND EMULATION
ꢀꢍ ꢒꢀꢏ
{OCIA}
ꢀꢍ ꢓꢀꢏ
RESERVED 1
ꢀꢍ ꢔꢀꢏ
RESERVED 2
To choose an Interface,
e.g. KEYBOARD:
1. Scan START OF CONFIGURATION
2. Scan KEYBOARD
3. Scan END OF CONFIGURATION
- 3 - SYMBOLOGIES
CODE 39
ꢀꢅꢇꢑꢀꢏ
OFF
ꢀꢅꢊꢑꢀ
ON
INTERLEAVED 2 OF 5
ꢀꢅꢇꢐꢀꢏ
ꢀꢅꢊꢐꢀꢏ
OFF
ON
STANDARD 2 OF 5
ꢀꢅꢇꢎꢀꢏ
ꢀꢅꢊꢎꢀꢏ
OFF
ON
MATRIX 2 OF 5
ꢀꢅꢇꢒꢀꢏ
ꢀꢅꢊꢒꢀꢏ
OFF
ON
CODABAR
ꢀꢅꢇꢓꢀꢏ
OFF
ꢀꢅꢊꢓꢀꢏ
ON
SYMBOLOGIES - 4 -
EAN-8
ꢀꢅꢇꢕꢀꢏ
OFF
ꢀꢅꢊꢕꢀ
ON
EAN-13/UPC-A
ꢀꢅꢇꢔꢀꢏ
OFF
ꢀꢅꢊꢔꢀꢏ
ON
UPC-E
ꢀꢅꢇꢖꢀ
OFF
ꢀꢅꢊꢖꢀ
ON
ISBN/ISSN
ꢀꢅꢇ ꢀ
ꢀꢅꢊ ꢀ
OFF
ON
EAN/UPC ADDON 2/5
ꢀꢅꢇꢗꢀ
ꢀꢅꢊꢗꢀ
OFF
ON
- 5 - SYMBOLOGIES
CODE 128
ꢀꢅꢇꢆꢀꢏ
OFF
ꢀꢅꢊꢆꢀꢏ
ON
CODE 93
ꢀꢅꢇꢈꢀ
ꢀꢅꢊꢈꢀ
OFF
ON
CHINESE 2 OF 5
ꢀꢅꢇꢊꢀ
ꢀꢅꢊꢊꢀꢏ
OFF
ON
{MSI/PLESSEY}
ꢀꢅꢇꢉꢀꢏ
ꢀꢅꢊꢉꢀ
OFF
ON
{CODE 11}
ꢀꢅꢇꢇꢀ
ꢀꢅꢊꢇꢀ
OFF
ON
SYMBOLOGIES- 6 -
{PHARMACEUTICAL CODE}
ꢀꢆꢆꢗꢀ
ꢀꢆꢆꢆꢀ
OFF
ON
{CODE IV}
ꢀꢅꢇꢘꢀꢏ
ꢀꢅꢊꢘꢀꢏ
OFF
ON
{CODE49}
ꢀꢅꢇꢌꢀꢏ
ꢀꢅꢊꢌꢀꢏ
OFF
ON
Itallian PharmaCode
“A”ꢀ
ꢀꢆꢆꢇꢀꢏꢏꢏꢏꢏꢏ
ꢀꢆꢆꢉꢀꢏ
OFF
ON
EAN-8 TO EAN-13
ꢀꢆꢌꢔꢀꢏ
ꢀꢆꢌꢓꢀꢏ
OFF
ON
In order to enable Italian PhamaCode,
PHARMACEUTICAL CODE should also be
enabled.
- 7 - CODE 39
TYPE
ꢀꢆꢆꢑꢀ
STANDARD
ꢀꢆꢆꢐꢀ
FULL ASCII
TRANSMIT START/STOP CHAR
ꢀꢆꢆꢎꢀꢏ
ꢀꢆꢆꢒꢀꢏ
OFF
ON
VERIFY CHECKSUN
ꢀꢆꢆꢓꢀ
ꢀꢆꢆꢔꢀ
OFF
ON
TRANSMIT CHECK CHAR
ꢀꢆꢆꢕꢀꢏ
ꢀꢆꢆꢖꢀ
OFF
ON
CODE39 LABEL ID
ꢀꢆꢆꢊꢀꢏ
ꢀꢆꢆ ꢀ
OFF
ON
CODABAR/NW7 - 8 -
TRANSMIT START/STOP
ꢀꢆꢊꢑꢀꢏ
ꢀꢆꢊꢐꢀꢏ
OFF
ON
TYPE OF START/STOP
ꢀꢆꢊꢎꢀ
ABCD/ABCD
ꢀꢆꢊꢒꢀ
ABCD/TN E
ꢀꢆꢊꢓꢀ
ꢀꢆꢊꢔꢀ
abcd/abcd
abcd/tn e
TRANSMIT CHECK DIGIT
ꢀꢆꢊꢕꢀꢏ
ꢀꢆꢊꢖꢀꢏ
OFF
ON
VERIFY CHECK DIGIT
ꢀꢆꢊꢗꢀ
ꢀꢆꢊꢆꢀ
OFF
ON
- 9 -INTERLEAVED 2 OF 5
BAR CODE LENGTH
ꢀꢆꢈꢑꢀꢏ
MINI. TO MAXI. = ? <6-32>
MINI.=2. MAXI.=32
ꢀꢆꢈꢐꢀꢏ
CUSTOM DEFINE
3 SETS AVAILABLE
TRANSMIT CHECK DIGIT
ꢀꢆꢈꢎꢀꢀ
ꢀꢆꢈꢒꢀꢏ
OFF
ON
VERIFY CHECK DIGIT
ꢀꢆꢈꢓꢀ
ꢀꢆꢈꢔꢀ
OFF
ON
INTERLEAVED 2 OF 5- 10 -
To choose BAR CODE LENGTH, e.g.
10 - 20, (0A,14 in Hex):
1. Scan START OF CONFIGURATION
2. Scan BAR CODE LENGTH
3. Scan 0
A
1
4
SET
4. Scan END OF CONFIGURATION
CUSTOM DEFINE, user may choose
1 to 3 individual lengths,
excluding the range between,
e.g. user wants lengths of 12,
16 and 20: (0C, 10 and 14 in Hex)
Use above example except:
No. 2. Scan CUSTOM DEFINE
No. 3. Scan 0 C 1 0 1 4 SET
- 11 -STANDARD 2 OF 5
BAR CODE LENGTH
ꢀꢆꢉꢑꢀꢏ
MINI. TO MAXI. = ? <6-32>
MINI.=2. MAXI.=32
ꢀꢆꢉꢐꢀꢏ
CUSTOM DEFINE
3 SETS AVAILABLE
TRANSMIT CHECK DIGIT
ꢀꢆꢉꢎꢀ
ꢀꢆꢉꢒꢀ
OFF
ON
VERIFY CHECK DIGIT
ꢀꢆꢉꢓꢀꢏ
ꢀꢆꢉꢔꢀꢏ
OFF
ON
See example on page 10
MATRIX 2 OF 5- 12 -
BAR CODE LENGTH
ꢀꢆꢇꢑꢀ
MINI. TO MAXI. = ? <6-32>
MINI.=2. MAXI.=32
ꢀꢆꢇꢐꢀ
CUSTOM DEFINE
3 SETS AVAILABLE
TRANSMIT CHECK DIGIT
ꢀꢆꢇꢎꢀ
ꢀꢆꢇꢒꢀ
OFF
ON
VERIFY CHECK DIGIT
ꢀꢆꢇꢓꢀ
ꢀꢆꢇꢔꢀꢏ
OFF
ON
See example on page 10
- 13 -
EAN-13/EAN-8
EAN-13
TRUNCATE LEADING DIGIT
S
ꢀꢆ ꢑꢀ
= ?
0
TRANSMIT CHECK DIGIT
ꢀꢆ ꢔꢀ
ꢀꢆ ꢓꢀꢏ
YES
NO
EAN-8
TRUNCATE LEADING DIGIT
S
ꢀꢆꢌꢑꢀ
= ?
0
TRANSMIT CHECK DIGIT
ꢀꢆꢌꢒꢀ
ꢀꢆꢌꢎꢀ
YES
NO
Example: user wants to truncate 1
(the first leading digit):
1. Scan START OF CONFIGURATION
2. Scan TRUNCATE LEADING DIGIT
3. Scan 0
1
SET
4. Scan END OF CONFIGURATION
UPC-A/UPC-E - 14 -
UPC-A
TRUNCATE LEADING DIGIT
S
ꢀꢆꢘꢑꢀ
= ?
0
TRANSMIT CHECK DIGIT
ꢀꢆꢘꢔꢀ
ꢀꢆꢘꢓꢀ
YES
NO
UPC-E
TRUNCATE LEADING DIGIT
S
ꢀꢆꢍꢑꢀ
= ?
0
TRANSMIT CHECK DIGIT
ꢀꢆꢍꢒꢀ
ꢀꢆꢍꢎꢀ
YES
NO
UPC-E TO UPC-A
ꢀꢆꢍꢓꢀꢏ
YES
ꢀꢆꢍꢔꢀ
NO
See example on page 13
- 15 -
CHINESE 2 OF 5
BAR CODE LENGTH
ꢀꢆꢙꢑꢀ
MINI. TO MAXI. = ? <6-32>
MINI.=2. MAXI.=32
ꢀꢆꢙꢐꢀ
CUSTOM DEFINE
3 SETS AVAILABLE
TRANSMIT CHECK DIGIT
ꢀꢆꢙꢎꢀ
ꢀꢆꢙꢒꢀ
OFF
ON
VERIFY CHECK DIGIT
ꢀꢆꢙꢓꢀ
ꢀꢆꢙꢔꢀ
OFF
ON
See example on page 10
READING MODES - 16 -
ꢀꢆꢚꢑꢀꢏ
TRIGGER ON/OFF
TRIGGER ON/
ꢀꢆꢚꢐꢀ
ꢏ
GOOD READ OFF
ꢀꢆꢚꢎꢀ
CONTINUOUS/
TRIGGER OFFꢏ
ꢀꢆꢚꢒꢀ
ꢀꢆꢚꢓꢀ
ꢀꢆꢚꢔꢀ
CONTINUOUS/
LED ALWAYS ON
TESTING
TRIGGER ON/
GOOD READ OFF/ꢏ
DELAY TIME = ?
ꢀꢆꢚꢕꢀ
ꢀꢆꢚꢖꢀ
CONTINUOUS/
GOOD READ OFF/
DELAY TIME = ?
CONTINUOUS/
NO TRIGGER
- 17 -
GENERAL PARAMETERS
TERMINATOR
NONE
CR KB
LF
CR/LF RS232
ꢀꢆꢛꢓꢀ
SPACE
ꢏ
TAB
ESC
CTRL-C
EXEC
EOT
STX..ETX
LED INDICATOR
ꢀꢆꢜꢎꢀ
OFF
ON
GENERAL PARAMETERS - 18 -
ꢀꢆꢛ ꢀ
TERMINATOR
DELAY = ?
<4> KEYBOARD
<0> RS232
ꢀꢆꢜꢑꢀ
ꢀꢆꢜꢐꢀ
BUZZER
PITCH = ? <18>
BUZZER <5>
DURATION = ?
TIME(S) OF DATA COMPARISON
ꢀꢆꢝꢓꢀ
TWO
ONE
POWER UP BEEPING
ꢀꢆꢝꢎꢀ
ꢀꢆꢝꢔꢀꢏ
ꢀꢆꢝꢒꢀꢏ
YES
NO
DATA FORMAT
ꢀꢆꢝꢑꢀꢏ
PREAMBLE/DATA/
POSTAMBLE/ TERMINATOR
ꢀꢆꢝꢐꢀꢏ
PREAMBLE/DATA/
TERMINATOR/ POSTAMBLE
- 19 -
GENERAL PARAMETERS
ꢀꢆꢋꢑꢀ
CHARACTER
DELAY = ?
<4> KEYBOARD
<0> RS232
ꢀꢆꢋꢒꢀ
INTERFIELD
DELAY = ?
<20>
SENDING NUMBER OF DIGITS
ꢀꢆꢝꢕꢀ
ꢀꢆꢝꢗꢀꢏ
OFF
ON
KEYBOARD PARAMETERS - 20 -
ꢀꢆ ꢐꢀ
LOWER CASE
ꢀꢆ ꢎꢀ
UPPER CASE
NUMBER KEYS
ꢀꢆ ꢔꢀ
ALPHANUM
NUMLOCK PAD
KEYBOARD SPEED
ꢀꢆ ꢒꢀ
ꢀꢆ ꢕꢀ
ꢀꢆ ꢓꢀ
NORMAL
TURBO
ꢀꢆꢋꢐꢀ
PREAMBLE
= ?
ꢀꢆꢋꢎꢀ
POSTAMBLE
= ?
10 Bytes each
CANCEL Preamble/postamble
ꢀꢌ!ꢝꢀ
*
Please read PREAMBLE or
POSTAMBLE label first
- 21 -TERMINAL TYPE
ꢀꢆ"ꢑꢀ
ꢀꢆ"ꢐꢀ
ꢀꢆ"ꢎꢀ
PC/AT,
PS/2 30-80
PC/XT
PS/2 25,30
IBM5541
ꢀꢆ"ꢒꢀ
IBM PS/55 ST
IBM 3472,3477
IBM 5530-SC
ꢀꢆ"ꢓꢀ
IBM PS/55 MP
IBM 5295
ꢀꢆ"ꢔꢀꢏ
ꢀꢆ"ꢕꢀꢏ
IBM 5530-ZC
NEC 9801
NEC 5262/N8VS2ꢀꢆ"ꢖꢀ
ꢀꢆ"ꢗꢀ
CT 500/700
TERMINAL TYPE- 22 -
ꢀꢆ"ꢆꢀꢏ
ꢀꢆ"ꢈꢀꢏ
ꢀꢆ"ꢉꢀꢏ
{Mac II,SE}
{WYSE}
{ACER D7300}
{WANG}
ꢀꢆ"ꢍꢀꢏ
ꢀꢆ"#ꢀꢏ
{THINK PAD}
IBM
- 23 -FUNCTION KEY
FUNCTION KEY EMULATION
ꢀꢆꢝꢆꢀ
ꢀꢆꢝꢈꢀ
ENABLE
DISABLE
Scanner can read Function keys and
other special keys, please refer
to FUNCTION KEY LABLES. When doing
this, Code 39 FULL ASCII must be
on.
To concatenate a Function Key or
other special keys with input data,
e.g. F1:
1. Scan START OF CONFIGURATION
2. Scan keyboard PREAMBLE
3. Scan 0 1 SET
4. Scan END OF CONFIGURATION
FUNCTION KEY TABLE -24-
H
0
1
L
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
BkSp
Home
PgUp
PgDn
END
F1
F2
F3
F4
F5
F6
F7
F8
F9
Ins
Del
Pad
F10
F11
F12
Etr
ESC
TAB
-25- FUNCTION KEY LABELS
ꢏ
ꢏ
F1
ꢏ
ꢏ
ꢏ
ꢏ
ꢏ
F2
ꢏ
F3
ꢏ
F4
F5
ꢏꢏ
F6
ꢏ
F7
F8
ꢏ
F9
ꢏ
F10
F11
F12
ꢏ
Enter
BkSp
ESC
TAB
Home
PgUp
FUNCTION KEY LABELS -26-
PgDn
ꢏ
End
ꢏ
Ins
Del
Pad
- 27 - LANGUAGES
ꢀꢆ$ꢑꢀ
BELGIAN
ꢏ ꢀꢆ$ꢐꢀ
DANISH
ꢀꢆ$ꢎꢀ
FRENCH
ꢀꢆ$ꢒꢀ
GERMANY
ꢀꢆ$ꢓꢀ
ITALIAN
ꢀꢆ$ꢔꢀ
PORTUGUESE
ꢀꢆ$ꢕꢀ
SPANISH
ꢀꢆ$ꢖꢀ
SWEDISH
ꢀꢆ$ꢗꢀ
SWISS
ꢀꢆ$ꢆꢀ
UK
ꢀꢆ$ꢈꢀꢏ
US
ꢀꢆ$ꢆꢀ
WYSIWYG
RS232 PARAMETERS - 28 -
BAUD RATE
ꢀꢆ!ꢑꢀ
300
ꢀꢆ!ꢐꢀꢏ
600
ꢀꢆ!ꢎꢀ
1200
ꢀꢆ!ꢒꢀꢏ
2400
ꢀꢆ!ꢓꢀ
4800
ꢀꢆ!ꢔꢀꢏ
9600
ꢀꢆ!ꢕꢀ
19200
ꢀꢆ!ꢖꢀꢏ
38400
DATA BIT
ꢀꢆ%ꢑꢀ
ꢀꢆ%ꢐꢀꢏ
7
8
STOP BIT
ꢀꢆ%ꢎꢀ
ꢀꢆ%ꢒꢀꢏ
1
2
- 29 - RS232 PARAMETERS
PARITY
ꢀꢆ&ꢑꢀ
ꢀꢆ&ꢐꢀꢏ
NONE
ODD
ꢀꢆ&ꢎꢀꢏ
SPACE
ꢀꢆ&ꢒꢀꢏ
EVEN
ꢀꢆ&ꢓꢀꢏ
MARK
HAND SHAKING
ꢏ ꢀꢆꢅꢑꢀ
ꢀꢆꢅꢒꢀꢏ
NONE
ACK/NAK
ꢀꢆꢅꢐꢀ
XON/XOFF
ꢀꢆꢅꢓꢀ
RTS/CTS
SCANNER READY
ꢀꢆꢅꢎꢀꢏ
RTS/CTS
DATA READY
RS232 PARAMETERS - 30 -
ACK/NAK Response Time
CTS Observation Time
ꢀꢈꢆꢑꢀ
300 msec
ꢀꢈꢆꢐꢀ
500 msec
ꢀꢈꢆꢎꢀ
1 sec
ꢀꢈꢆꢒꢀꢏ
2 sec
ꢀꢈꢆꢓꢀ
3 sec
ꢀꢈꢆꢔꢀ
5sec
ꢀꢈꢆꢆꢀꢏ
∞
ꢀꢆꢋꢐꢀ
PREAMBLE
= ?
ꢀꢆꢋꢎꢀ
POSTAMBLE
= ?
10 Bytes each
CANCLE PREAMBLE/POSTAMBLE
ꢀꢌ!ꢝꢀꢏ
* Please read PREAMBLE or
POSTAMBLE lable first
- 31 -CCD WAND EMULATION
ꢀꢆ'ꢑꢀ
ꢀꢆ'ꢐꢀ
BAR=HIGH
BAR=LOW
SCAN SPEED
ꢀꢆ'ꢎꢀꢏ
SLOWEST
(28cm/sec)
ꢀꢆ'ꢒꢀꢏ
SLOW
(36cm/sec)
ꢀꢆ'ꢓꢀ
NORMAL
(49cm/sec)
ꢀꢆ'ꢔꢀ
HIGH
(80cm/sec)
ꢀꢆ'ꢕꢀꢏ
HIGHEST
(208cm/sec)
BASE ON 0.125 mm BAR CODE
OCIA - 32 -
OCIA MACHINES
ꢀ ꢀꢆ"ꢇꢀꢀ
ꢀ ꢀꢆ"ꢊꢀꢀ
CASIO
ꢀ ꢀ ꢀ
SIEMENS
ꢀ ꢀꢆ" ꢀꢀ
NIXDORFꢀ ꢀ ꢀꢆ"ꢘꢀꢀ
ꢀ ꢀ ꢀ
ꢏ ꢀꢆ"ꢌꢀꢏ
NCR-Fꢀꢀ ꢀ ꢀꢆ"ꢇꢀꢏ
NCR-S
ꢀ ꢀ
TEC
- 33 - MAGNETIC SETTING
TRACK DELIMITER
ꢏ ꢀꢈꢇꢑꢀꢏ
ꢏ ꢏꢏ ꢏ ꢀꢈꢇꢐꢀꢏ
NONE
CR
ꢏ ꢀꢈꢇꢎꢀꢏ
ꢏ ꢏꢏ ꢏ ꢏ ꢀꢈꢇꢒꢀꢏ
LF
CR/LF
ꢏ ꢀꢈꢇꢓꢀꢏ
SPACE
TRACK SELECTION
ꢀ ꢀꢈꢊꢑꢀꢏ
ꢀ
ꢀ ꢀꢈꢊꢐꢀꢏ
TRACK 1
TRACK 2
ꢀ ꢀꢈꢊꢎꢀꢏ
ꢀ
ꢀ ꢀꢈꢊꢒꢀ
TRACK 3
ꢀ
TRACK 1&2
ꢀ ꢀꢈꢊꢓꢀꢏ
ꢀ
TRACK 2&3ꢀꢀ ꢀꢈꢊꢔꢀ
{TRACK 1,2&3}
CODE MARK- 34 -
ꢀꢆ(ꢑꢀ
CODE 39 = ?ꢀꢆ(ꢐꢀꢏ
ITF 2/5 = ?
ꢀꢆ(ꢎꢀ
STD 2/5 = ?
ꢀꢆ(ꢒꢀꢏ
MTX 2/5 = ?
ꢀꢆ(ꢓꢀꢏ
CODABAR = ?
ꢀꢆ(ꢔꢀꢏ
EAN-13 = ?
ꢀꢆ(ꢕꢀ
UPC-A = ?
ꢀꢆ(ꢖꢀ
EAN-8 = ?
ꢀꢆ(ꢗꢀ
UPC-E = ?
ꢀꢆ(ꢆꢀ
{CODE 11 = ?}
ꢀꢆ(ꢈꢀ
CODE 93 = ?ꢀꢆ(ꢉꢀꢏ
CHINESE 2/5 = ?
ꢀꢆ(ꢇꢀꢏ
CODE 128 = ?
ꢀꢆ( ꢀꢏ
{MSI = ?}
- 35 - CODE MARK
ꢏ ꢀꢆ(ꢊꢀ
ꢀꢆ(ꢑꢀꢏ
{CODE IV}
{PHARMACEUTICAL}
CODE MARK CANCELLATION
ꢀꢌ!ꢝꢀꢏ
* Read code type first
CODE MARK
ꢀꢆꢝꢊꢀꢏ
ON
ꢀꢆꢝ ꢀꢏ
OFF
TRUNCATE LEADING DIGIT - 36 -
ꢀꢈꢈꢎꢀꢏ
CODE 39
ꢀꢈꢈꢒꢀꢏ
ꢀꢈꢈꢓꢀꢏ
CODABAR
MATRIX 2/5
STANDARD 2/5
ꢏ ꢀꢈꢈꢔꢀꢏ
ꢀꢈꢈꢕꢀꢏ
INTERLEAVED
2/5
ꢀꢈꢈꢖꢀꢏ
CODE 128
CODE 93
ꢀꢈꢈꢗꢀꢏ
PHARMACEUTICALꢏꢀꢈꢈꢎꢀꢏ
ꢀꢈꢈ ꢀ
CODE IV
User can choose only 1 symbology
at a time to truncate leading or
ending digits.
At the same time, the TRUNCATE
functions of EAN and UPC codes
can also be operating.
- 37 - TRUNCATE ENDING DIGIT
ꢀꢈꢉꢎꢀ
CODE 39
ꢀꢈꢉꢒꢀ
CODABAR
ꢏ ꢀꢈꢉꢓꢀ
MATRIX 2/5
ꢀꢈꢉꢔꢀ
STANDARD 2/5
ꢀꢈꢉꢕꢀ
INTERLEAVED
2/5
ꢀꢈꢉꢖꢀ
CODE 128
ꢀꢈꢉꢗꢀ
CODE 93
ꢀꢈꢉꢎꢀꢏ
PHARMACEUTICAL
ꢀꢈꢉ ꢀꢏ
CODE IV
ꢀꢈꢉ)ꢀ
EAN-13
ꢀꢈꢉꢑꢀ
EAN-8
ꢀꢈꢉꢐꢀ
UPC-E
ꢀꢈꢉꢘꢀ
UPC-A
ASCII TABLE - 38 -
ꢀꢁꢂꢃꢄꢀꢏ
START
CONFIGURATION
ꢀꢆꢈꢉ ꢀꢏ
ꢀꢊꢋꢉ ꢀꢏ
ABORT
CONFIGURATION
END
CONFIGURATION
ASCII TABLE
H
0
1
2
3
4
5
6
7
L
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
NUL DLE SP
0
1
2
3
4
5
6
7
8
9
:
@
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
[
'
a
b
c
d
e
f
g
h
i
j
k
l
m
n
o
p
q
r
s
t
u
v
w
x
y
z
{
SOH DC1
STX DC2
ETX DC3
EOT DC4
ENQ NAK
ACK SYN
BEL ETB
BS CAN
!
"
#
$
%
&
'
(
HT
EM
)
LF SUB
VT ESC
*
+
,
-
.
;
FF
CR
SO
SI
FS
GS
RS
US
<
=
>
?
\
]
^
_
|
}
/
DEL
- 39 - HEXADECIMAL LABELS
ꢏ ꢀ ꢏ
0
ꢏ ꢀ ꢀ ꢀ ꢀ ꢏ
1
ꢏ ꢏ ꢏ ꢏ ꢏ ꢏ ꢏ
2
ꢏ
ꢀ ꢀ ꢏ ꢏ
3
ꢀ ꢏ ꢏ ꢀ ꢀ ꢏ ꢏ
4
ꢏ ꢏ
ꢏ ꢏ
5
ꢏ
ꢀ ꢀ ꢏ
6
ꢏ ꢀ ꢀ ꢀ ꢀ ꢀ ꢏ
7
8
ꢏ
ꢏ ꢀ ꢀ ꢏ
9
Aꢀ ꢀ
B
ꢏ
ꢏ ꢀ ꢀ ꢏ
C
ꢏ ꢀ ꢀ ꢀ ꢀ ꢀ
D
E
ꢏ
ꢏ ꢏ ꢏ ꢏ ꢀꢁꢂꢃꢀ
F
ꢏ ꢏ ꢏ ꢏ ꢏ
SET
PIN ASSIGNMENTS - 40 -
TTL Signal Output
COLOR
FUNCTION
9 PIN
5 PIN
6 PIN
6 PIN MINI
DSUB/AMP (F) DIN (M)
DIN (M)
DIN (M)
BROW
YELLO
GREEN
RED
BLUE
BLACK
PURPLE
START OF SCAN
SIGANLDATA
LED INDICATOR
TRIGGER
POWER ENABLE
GND
1
2
3
5
6
7
8
9
-
2
-
5
4
3
3
1
6
2
-
5
4
3
3
1
6
4
-
1
2
5
5
3
GND SHIELD
ORANGE Vcc +5V
CCD Wand Emulation Signal Output
COLOR
BLUE
BROW
PURPLE
FUNCTION
SIGNAL DATA
GND
9 PIN DSUB/AMP (F) 5 PIN DIN (M) 6 PIN DIN (M)
2
8
9
2
3
1
2
3
1
Vcc +5V
NOTE: The pin number for the 5 and 6 pin connectors are viewed internally.
F stands for a female connector while M stands for a male connector.
- 41 - PIN ASSIGNMENTS
RS232 SIGNAL OUTPUT
COLOR
BROW
YELLO
GREEN
ORANGE RX
BLUE
FUNCTION
GND
CTS
9 PIN DSUB/AMP (F) 25 PIN DSUB (F)
5
8
7
2
3
9
7
4
5
2
3
RTS
TX
Vcc +5V
PURPLE
25,16
PIN ASSIGNMENTS - 42 -
RS232/Keyboard Signal Output
COLOR
BROW
BLUE
PURPLE
ORANGE RX
FUNCTION
GND
TX
9 PIN DSUB/AMP (F) 25 PIN DSUB (F)
5
3
9
2
7
3
Vcc +5V
25,16
2
NOTE: RS232 CABLE WITH DC POWER SOCKET FOR DC POWER 5V
OCIA Signal Output
COLOR
RED
ORANGE CLOCK
GREEN
BLUE
WHITE
BROW
FUNCTION
CLOCK RETURN
8 PIN DIN (M) 9 PIN DB-(F)
10 PIN
4
3
1
2
5
7
1
2
3
4
7
8
3
9
5
7
10
1
DATA RETURN
DATA
VCC
GND
Asia Pacific
PSC Hong Kong
Germany
PSC GmbH
Latin America
PSC S.A., INC.
Hong Kong
Telephone: [852]-2-584-6210
Fax: [852]-2-521-0291
Darmstadt, Germany
Telephone: 49 (0) 61 51/93 58-0
Fax: 49 (0) 61 51/93 58 58
Miami, Florida, USA
Telephone: (305) 539-0111
Fax: (305) 539-0206
Australia
PSC Asia Pacific Pty Ltd.
North Ryde, Australia
Telephone: [61] 0 (2) 9878 8999
Fax: [61] 0 (2) 9878 8688
Italy
PSC S.p.A.
Vimercate (MI), Italy
Telephone: [39] (0) 39/62903.1
Fax: [39] (0) 39/685496
United Kingdom
PSC Bar Code Ltd.
Watford, England
Telephone: 44 (0) 1923 809500
Fax: 44 (0) 1923 809 505
France
PSC S.A.R.L.
Japan
PSC Japan K.K.
Switzerland
GOMARO s.a.
LES ULIS Cedex, France
Telephone: [33].01.64.86.71.00
Fax: [33].01.64 46.72.44
Shinagawa-ku, Tokyo, Japan
Telephone: 81 (0)3 3491 6761
Fax: 81 (0)3 3491 6656
CH 1123 Aclens
Telephone: [41] (0)21 869 97 70
Fax:
[41] (0)21 869 96 02
Corporate Headquarters
PSC Inc.
PSC Inc.
959 Terry Street
Portland, OR
Eugene, OR
Telephone: (503) 534-3553
Fax: (503) 534-3555
Telephone: (541) 683-5700
Fax: (541) 686-1702
©PSC INC
.
R44-2012 (Rev. A)
Printed in USA 10/01
|